BreathMo®: The New Generation ECMO system Revealed at ASAIO Conference

Last month, the American Society for Artificial Internal Organs (ASAIO) 68th Yearly Fulfilling was efficiently kept in San Francisco. magAssist's item, BreathMo ® was highlighted in the conference.

Dr. Dong Guo from Beijing Anzhen Hospital, presented the advancement of the gadget featured in a research titled "A 14-Day In-Vivo Evaluation of a Newly Developed Maglev ECMO System BreathMo ®, "demonstrating its efficiency and safety and security for providing both pulmonary and heart support.

A life-saving device that experienced rapid growth with 40% CAGR in China

Extracorporeal Membrane Oxygenation (ECMO) offers essential support for critical care unit (ICU) people, 60% of whom develop heart or respiratory failure with a death price of 23-75%. In China, ECMO has actually become an important mechanical blood circulation assistance (MCS) for critically ill clients with information revealing that the variety of ECMO cases has enhanced nearly fourfold from 2,826 in 2017 to 10,656 in 2021. (Data from the China ECMO Report 2021 and the study of the Extracorporeal Life Support Committee of the Chinese Medical Doctor Association).

The expanding need for ECMO is also fueled by the COVID-19 pandemic, during which extended ECMO assistance was frequently made use of to deal with those who struggle with serious signs. The restriction of the existing ECMO systems revealed the demand for clinical device manufacturers to upgrade ECMO gadgets geared up with sophisticated features. These functions consist of a complete maglev pump with higher hemocompatibility, an oxygenator with high gas exchange efficiency and low cross-oxygenator pressure drop, aiming to provide long-term life-saving support to patients in need.

The newly developed ECMO, delivering greater performance and safety.

During the conference, Dr. Guo pointed out that it is essential to develop ECMOs with full maglev centrifugal pumps, which might much better sustain people in the future. The complete maglev centrifugal pumps have actually emerged as an extremely appealing service, providing exceptional hemocompatibility, and presenting potential engineering technologies for lasting ECMO or membrane layer applications.

Centrifugal blood pumps are regularly used in grown-up ECMO, and the majority of them depend on pivot bearing, which has a lower hemocompatibility compared with full maglev pumps. Furthermore, the high rotational speed can cause high shear stress and anxiety, possibly bring about hemolysis.

A journal short article in Medicine and Novel Technology and Devices examined the hemolytic efficiency of pumps in grown-up ECMO support, which highlighted the enhanced safety and security and efficiency of the full maglev circulation modern technology. These computational findings were further sustained by experimental results, showing that the maglev pump triggered the least damage to blood cells when contrasted to the Revolution and Rotaflow pumps.

BreathMo ®, China's organic maglev ECMO system that deals with the unmet medical demands of Chinese clients.

To bridge professional spaces in China, magAssist has created a new generation ECMO system, BreathMo ®. The use of maglev modern technology minimizes the risk of blood damages triggered by mechanical contact bearings, causing much safer procedure. The maglev pump shows superior hemocompatibility with total low blood damage at the hemolysis degree and degradation of high-molecular-weight (VWF).

As stated in the seminar, the system's flow price of up to 7L/min is enhanced by an oxygenator that preserve remarkable efficiency, using a low-pressure drop (much less than 50mmHg) even at optimum flow prices. Significantly, the tool integrates an ultra-compact portable console evaluating less than 8 kg, permitting healthcare specialists to tailor therapy to private person requirements.

In the research developed to evaluate the in-vivo efficiency and safety of BreathMo ®, the last health condition of the ten lamb selected for the test, with five going through VA cannulation and the remaining 5 undertaking VV cannulation, verified the system's capability to supply lung and cardiac assistance.

The research study disclosed their plasma-free hemoglobin levels were within an appropriate range, with constantly optimal oxygenator efficiency. The PFH values ranged from 0.36 to 14.80 mg/dL, much below 40 mg/dL which is an indication of possible thrombus development.

The postmortem examination evaluations performed after the research study revealed no complications, blood clot, thrombus formation, or end-organ damage, without device-related unfavorable occasions reported, further verifying the system's safety and security profile and leading the way for its first-in-human studies trial in the future.

surgically cannulated extracorporeal artificial hearts The development of BreathMo ® marks one more technological turning point as we look for brand-new ingenious life-saving remedies to boost person health while empowering healthcare professionals to improve their treatment results. With our ingenious maglev innovation that enables great hemocompatibility, BreathMo ® not just supplies risk-free and reliable cardiopulmonary assistance yet is also a new promising starting point as we continue to leverage industry and technical resources to unlock new possibilities for the ECMO field," Dr. Chiahao Hsu, Senior Director of Science and Innovation Department of magAssist.